| Stillwater |
CP_361 |
2026-07-07 |
Other |
TRIPLE J |
1
|
Missing Vault picture |
| Stillwater |
VERO_S_SEGMENT3_CON |
2026-07-06 |
Missing_Installation |
Carey |
2
|
No tracer wire |
| Stillwater |
VERO_N_SEGMENT3_CON |
2026-07-06 |
Restoration_Backfill |
MB Directional |
2
|
|
| Stillwater |
VERO_S_SEGMENT3_CON |
2026-07-06 |
Restoration_Backfill |
TRIPLE J |
2
|
Homeowner is very upset. He finally got the ditch fixed to where he can mow and the ditch line was rutted up and not back filled properly so he can mow. Please get this corrected ASAP. |
| Stillwater |
VERO_N_SEGMENT3_CON |
2026-07-02 |
Conduit_Depth |
MB Directional |
6
|
Conduit not at depth entire length of run |
| Stillwater |
VERO_N_SEGMENT3_CON |
2026-07-02 |
Restoration_Trench |
MB Directional |
6
|
80 foot of conduit not at depth conduit needs to be removed and dirt needs to be restored |
| Stillwater |
VERO_S_SEGMENT3_CON |
2026-07-01 |
Restoration_Backfill |
Unassigned |
7
|
Open hole needs backfilled |
| Stillwater |
VERO_N_SEGMENT3_CON |
2026-07-01 |
Restoration_Backfill |
MB Directional |
7
|
Ground sinking |
| Stillwater |
VERO_N_SEGMENT3_CON |
2026-06-30 |
Pole_Continuitybond |
TRIPLE J |
8
|
The tracer wires that are supposed to be in the marker. Post test station are tied to the ground rod. |
| Stillwater |
VERO_N_SEGMENT3_CON |
2026-06-30 |
Restoration_Softscape |
TRIPLE J |
8
|
|
| Stillwater |
VERO_N_SEGMENT3_CON |
2026-06-30 |
Pole_Continuitybond |
TRIPLE J |
8
|
No tracer wire in the marker post it’s also full of water |
| Stillwater |
VERO_S_SEGMENT3_CON |
2026-06-23 |
Other |
TRIPLE J |
15
|
missing pictures |
| Stillwater |
VERO_S_SEGMENT3_CON |
2026-06-23 |
Restoration_Core_Hole |
MB Directional |
15
|
Needs sand and concrete replaced |
| Stillwater |
VERO_S_SEGMENT3_CON |
2026-06-22 |
Pole_Grounding |
TRIPLE J |
16
|
Tracer wire needs to be placed in marker post |
| Stillwater |
VERO_S_SEGMENT3_CON |
2026-06-22 |
Other |
TRIPLE J |
16
|
Needs pictures |
| Stillwater |
VERO_S_SEGMENT3_CON |
2026-06-22 |
Restoration_Backfill |
TRIPLE J |
16
|
Vault must be level with the surface of the ground |
| Stillwater |
VERO_S_SEGMENT3_CON |
2026-06-22 |
Splice_Closure_Grounding |
TRIPLE J |
16
|
Grounding rod must be 2-4 inches max above gravel |
| Stillwater |
VERO_N_SEGMENT3_CON |
2026-06-22 |
Restoration_Backfill |
Global Pipeline |
16
|
Volt must be level with the surface of the ground, sides must not be visible |
| Stillwater |
VERO_N_SEGMENT3_CON |
2026-06-22 |
Locate_Other |
Global Pipeline |
16
|
All three trace wires must be connected in the market post |
| Stillwater |
VERO_S_SEGMENT3_CON |
2026-06-17 |
Structure_Grounding |
TRIPLE J |
21
|
Tracer wire not connected properly. |
| Stillwater |
VERO_S_SEGMENT3_CON |
2026-06-11 |
Structure_Grounding |
TRIPLE J |
27
|
As stated in the spec book, the grounding rod is to be 2 to 4 inches in length above ground |
| Stillwater |
VERO_S_SEGMENT3_CON |
2026-06-11 |
Restoration_Other |
TRIPLE J |
27
|
Voltage to be level with the surface of the ground all sinkage must be filled in |
| Stillwater |
VERO_S_SEGMENT3_CON |
2026-06-09 |
Conduit_Length |
TRIPLE J |
29
|
As stated in the spec book conduit is to be 6 to 12 inches in length |
| Stillwater |
VERO_S_SEGMENT3_CON |
2026-06-04 |
Other |
TRIPLE J |
34
|
Missing tracer wire. Wrong gauge ground wire. |
| Stillwater |
VERO_S_SEGMENT3_CON |
2026-06-04 |
Other |
TRIPLE J |
34
|
No marker post no acorn on the ground rod and I only see one side of the tracer wire |
| Stillwater |
VERO_S_SEGMENT3_CON |
2026-04-24 |
Locate_Continuity |
Carey |
75
|
Missing tracer wire |