City Project Created Type Crew Age (days) ↓ Comments
Denver DEN201e-907 2026-03-25 Restoration_Core_Hole DTOB 105 Several sunken core holes on 38th
Denver DEN201d-905 2026-04-10 Trash_Scraps DTOB 89 Site clean up needed
Denver DEN201d-905 2026-04-14 Restoration_Hardscape_Asphalt DTOB 85 Damage to trench
Denver DEN201d-905 2026-04-21 Restoration_Core_Hole DTOB 78 Pot hole needs to be filled
Stillwater VERO_S_SEGMENT3_CON 2026-04-24 Locate_Continuity Carey 75 Missing tracer wire
Denver DEN201d-905 2026-05-01 Restoration_Core_Hole DTOB 68 Pot hole needs to be filled
Logan N147b-N120 2026-05-04 Conduit_Length GTO 65 Trim conduit to 3-6 inches
Logan N147b-N120 2026-05-04 Conduit_Length GTO 65 Trim conduit to 3-6 inches
Denver DEN201e-908 2026-05-06 Structure_Grounding DTOB 63 Needs Ground/Grounding
Denver DEN201e-908 2026-05-06 Structure_Grounding DTOB 63 Needs Ground/Grounding
Denver DEN201e-908 2026-05-06 Structure_Grounding DTOB 63 Needs Ground/Grounding
Denver DEN201d-905 2026-05-07 Restoration_Core_Hole DTOB 62
Denver DEN201d-905 2026-05-12 Trash_Scraps DTOB 57 Big piles of dirt and flow fill left behind.
Denver DEN201d-905 2026-05-12 Restoration_Trench DTOB 57 Damage to flow fill in trench
Denver DEN201c-904 2026-05-14 Restoration_Trench DTOB 55 Damage control on trench
Mesa EDF phase 1 2026-05-14 Restoration_Core_Hole Foxfiber 55 Mastic skip
Mesa EDF phase 1 2026-05-14 Restoration_Trench Foxfiber 55 Mastic skip
Denver DEN201c-904 2026-05-21 Restoration_Core_Hole DTOB 48 Under filled potholes and trench in several places.
Denver DEN201b-902 2026-05-26 Structure_Grade_Level U Lineman 43 Vault not grade level
Mesa 121E-DF-PH01 2026-05-27 Structure_Grade_Level Diamond 42 Vault needs to be raised up to rock level
Denver DEN201e-908 2026-05-28 Structure_Grounding DTOB 41 Needs to be grounded
Mesa 121e-N152 2026-05-28 Restoration_Trench Foxfiber 41 Hot patch
Denver DEN201d-905 2026-06-03 Structure_Grounding U Lineman 35 Needs to be grounded
Denver DEN201d-905 2026-06-03 Structure_Grounding U Lineman 35 Needs grounding
Denver DEN201d-905 2026-06-03 Structure_Grounding U Lineman 35 Need conduit cut back and needs to be grounded
Denver DEN201d-905 2026-06-03 Structure_Grounding U Lineman 35 Need 6 gage cooper and wire nut
Denver DEN201d-905 2026-06-03 Structure_Grounding DTOB 35 Needs to be grounded
Denver DEN201d-905 2026-06-03 Structure_Grounding U Lineman 35 Needs to be grounded and conduit is to short
Denver DEN201d-905 2026-06-03 Structure_Grounding U Lineman 35 Needs to be grounded and conduit is to short
Denver DEN201d-905 2026-06-03 Structure_Grounding U Lineman 35 Needs to be grounded
Denver DEN201d-905 2026-06-03 Structure_Grounding DTOB 35 Needs to be grounded
Denver DEN201d-905 2026-06-03 Structure_Grounding DTOB 35 Needs to be grounded
Denver DEN201d-905 2026-06-03 Structure_Grounding DTOB 35 Needs to be grounded
Denver 2026-06-03 Structure_Grounding DTOB 35 Needs to be grounded
Denver DEN201b-902 2026-06-04 Structure_Grounding U Lineman 34 Needs to be grounded
Denver DEN201b-902 2026-06-04 Structure_Grounding U Lineman 34 Needs to be grounded
Denver DEN201b-902 2026-06-04 Structure_Grounding U Lineman 34 Needs 6 gage copper and wire nut and Vault is damaged
Denver DEN201b-902 2026-06-04 Structure_Grounding U Lineman 34 Needs the 6 gage copper and wire nut
Mesa PHX121 AB-DF 2026-06-04 Locate_Continuity PROCORP 34 Trace wire needs bonded
Mesa PHX121e-N142 2026-06-04 Restoration_Trench URIBE 34 Still has cold patch. Will need to be a hot patch now due to cars running over.
Stillwater VERO_S_SEGMENT3_CON 2026-06-04 Other TRIPLE J 34 Missing tracer wire. Wrong gauge ground wire.
Stillwater VERO_S_SEGMENT3_CON 2026-06-04 Other TRIPLE J 34 No marker post no acorn on the ground rod and I only see one side of the tracer wire
Denver 1 2026-06-05 Structure_Grounding DTOB 33 Needs to be grounded
Denver DEN201c-904 2026-06-05 Structure_Grounding DTOB 33 Needs to be grounded
Denver DEN201b-902 2026-06-05 Structure_Grade_Level U Lineman 33 Vault is not grade level
Denver DEN201b-902 2026-06-05 Structure_Grade_Level U Lineman 33 Vault not grade level
Denver DEN201b-902 2026-06-05 Structure_Grade_Level U Lineman 33 Vault not grade level
Denver DEN201b-902 2026-06-05 Structure_Grounding U Lineman 33 Need 6 gage copper and wire nut
Mesa 121e-DF-ph01 2026-06-05 Restoration_Trench Foxfiber 33 Mastic patch
Mesa 121-176 2026-06-06 Restoration_Softscape Ervin 32 Sinkhole next to vault
Denver DEN201b-902 2026-06-08 Structure_Grounding U Lineman 30 Need 6 gage and wire nut, also sleeve to long
Denver DEN201b-902 2026-06-08 Structure_Other U Lineman 30 Tracer not connected
Mesa 121E-N152 2026-06-08 Restoration_Trench Ervin 30 Mastic patch / iron down mastic
Logan Lgu147b-N117 2026-06-09 Locate_Isolation_Switch GTO 29 install isolation switch. Strip tracer wires and attach them to the isolation switch. Attach the Ground wire to the isolation switch.
Stillwater VERO_S_SEGMENT3_CON 2026-06-09 Conduit_Length TRIPLE J 29 As stated in the spec book conduit is to be 6 to 12 inches in length
Mesa PHX121e-N142 2026-06-10 Restoration_Core_Hole URIBE 28 Has cold patch on core
Mesa PHX121e-N142 2026-06-10 Restoration_Trench URIBE 28 Cold patch in trench
Mesa PHX121e-N142 2026-06-10 Restoration_Core_Hole URIBE 28 Cold patch in core
Mesa PHX121e-N142 2026-06-10 Restoration_Core_Hole URIBE 28
Mesa PHX121 E-DF-PH01 2026-06-10 Restoration_Trench Foxfiber 28 Mastic
Mesa 121E-DF-Ph1 2026-06-10 Restoration_Trench Foxfiber 28 Mastic skip/Out of town at the moment
Stillwater VERO_S_SEGMENT3_CON 2026-06-11 Structure_Grounding TRIPLE J 27 As stated in the spec book, the grounding rod is to be 2 to 4 inches in length above ground
Stillwater VERO_S_SEGMENT3_CON 2026-06-11 Restoration_Other TRIPLE J 27 Voltage to be level with the surface of the ground all sinkage must be filled in
Mesa 121e-N150 2026-06-12 Restoration_Core_Hole Foxfiber 26 Mastic core x2
Mesa 121e-N150 2026-06-12 Restoration_Trench Foxfiber 26 Mastic patch
Mesa PHX E-DF-PH01 2026-06-12 Restoration_Core_Hole Diamond 26 Needs mastic
Oregon MED_ZONE163_DA01_CON 2026-06-12 Unspecified Ervin 26 Trench span missing photos.
Mesa 121c-N127 2026-06-15 Structure_Other Ervin 23 Broken lid
Mesa 121c-N127 2026-06-15 Structure_Labeling Ervin 23 Fix label
Mesa 121c-N127 2026-06-15 Structure_Labeling Ervin 23 Fix label
Mesa 121c-N127 2026-06-15 Structure_Other Ervin 23 Fix label
Mesa 121c-N127 2026-06-15 Structure_Other REDLINE 23 Backfill
Oregon MED_HUT11_DA02_CON 2026-06-15 Fiber_Other Unassigned 23 Slackloop missing photo
Mesa 121e-N150 2026-06-16 Restoration_Trench Foxfiber 22 Mastic patch x3
Mesa 121e-N150 2026-06-16 Restoration_Trench Foxfiber 22 Mastic patch
Mesa 121c-n127 2026-06-16 Structure_Other REDLINE 22 Backfill
Denver DEN201e-908 2026-06-17 Structure_Gravel U Lineman 21 Needs more grave
Denver DEN201e-908 2026-06-17 Structure_Gravel U Lineman 21 Needs more gravel
Denver 1 2026-06-17 Structure_Gravel U Lineman 21 Need some more gravel
Denver DEN201e-908 2026-06-17 Structure_Gravel U Lineman 21 Need more gravel
Denver DEN201e-908 2026-06-17 Structure_Gravel U Lineman 21 To much dirt
Denver DEN201e-908 2026-06-17 Restoration_Other U Lineman 21 To much dirt
Denver DEN201e-908 2026-06-17 Restoration_Other U Lineman 21 Extra dirt
Mesa 121-141 2026-06-17 Restoration_Trench Foxfiber 21 Mastic patch over core hole
Mesa 121k-139 2026-06-17 Restoration_Trench Foxfiber 21 Mastic patches x5
Mesa 121k-139 2026-06-17 Restoration_Trench Foxfiber 21 Mastic patch
Mesa 121e-n150 2026-06-17 Restoration_Core_Hole Foxfiber 21 Mastic patch
Mesa 121e-n150 2026-06-17 Structure_Grade_Level URIBE 21 Level vault
Stillwater VERO_S_SEGMENT3_CON 2026-06-17 Structure_Grounding TRIPLE J 21 Tracer wire not connected properly.
Denver DEN201b-902 2026-06-18 Structure_Gravel U Lineman 20 Vault needs to be leveled/ martial inside Vault
Denver DEN201b-902 2026-06-18 Damaged_Material U Lineman 20 Broken Vault
Mesa 121k-142 2026-06-18 Restoration_Trench Foxfiber 20 Mastic patches
Oregon MED_ZONE164_DA02_CON 2026-06-19 Restoration_Softscape Unassigned 20 clean up rocks around vault
Denver DEN201b-902 2026-06-19 Structure_Other U Lineman 19 DV broken
Denver DEN201b-902 2026-06-19 Structure_Grade_Level U Lineman 19
Mesa PHX121 E-DF PH02 2026-06-19 Restoration_Softscape URIBE 19 Gravel gone from vault where uribe vacced out/Gray rock next to vault where uribe vacced for stubout.
Mesa PHX121-E-DF-PH02 2026-06-19 Structure_Grade_Level Diamond 19 Gravel needed / conduit needs to be capped or taped
Oregon MED_HUT09_DA01_CON 2026-06-19 Restoration_Trench Unassigned 19 Photo showing mastic skips under car. Mastic will need to be completed with a new photo
Oregon MED_ZONE164_DA02_CON 2026-06-19 Restoration_Softscape Unassigned 19 remove rocks from softscape around vault
Mesa PHX121-E-DF 2026-06-20 Damaged_Material Diamond 18 Cracked sidewall in T8, needs replacement.
Denver DEN201b-902 2026-06-22 Structure_Grounding U Lineman 16 Missing copper rod - end of line
Denver DEN201b-902 2026-06-22 Structure_Gravel U Lineman 16
Denver DEN201b-902 2026-06-22 Structure_Gravel U Lineman 16 Water in vault
Denver DEN201b-902 2026-06-22 Structure_Grade_Level U Lineman 16
Denver DEN201b-902 2026-06-22 Structure_Grade_Level U Lineman 16 Vault uneven
Denver DEN201b-902 2026-06-22 Structure_Other U Lineman 16 Lid need to be replaced
Mesa 121k-n142 2026-06-22 Restoration_Trench Foxfiber 16 Mastic patch
Mesa 121e-N152 2026-06-22 Restoration_Trench Foxfiber 16 Mastic skip
Mesa 121e-N152 2026-06-22 Restoration_Trench Foxfiber 16 Mastic patch X2
Mesa 121e-N152 2026-06-22 Restoration_Trench Foxfiber 16 Mastic skip
Stillwater VERO_S_SEGMENT3_CON 2026-06-22 Pole_Grounding TRIPLE J 16 Tracer wire needs to be placed in marker post
Stillwater VERO_S_SEGMENT3_CON 2026-06-22 Other TRIPLE J 16 Needs pictures
Stillwater VERO_S_SEGMENT3_CON 2026-06-22 Restoration_Backfill TRIPLE J 16 Vault must be level with the surface of the ground
Stillwater VERO_S_SEGMENT3_CON 2026-06-22 Splice_Closure_Grounding TRIPLE J 16 Grounding rod must be 2-4 inches max above gravel
Stillwater VERO_N_SEGMENT3_CON 2026-06-22 Restoration_Backfill Global Pipeline 16 Volt must be level with the surface of the ground, sides must not be visible
Stillwater VERO_N_SEGMENT3_CON 2026-06-22 Locate_Other Global Pipeline 16 All three trace wires must be connected in the market post
Denver DEN201b-902 2026-06-23 Structure_Grounding U Lineman 15
Denver DEN201c-903 2026-06-23 Structure_Grounding DTOB 15
Denver DEN201c-904 2026-06-23 Structure_Grounding Paramount Underground 15
Denver DEN201c-904 2026-06-23 Structure_Grounding DTOB 15
Denver DEN201c-904 2026-06-23 Structure_Grounding DTOB 15 Missing ground
Denver DEN201c-904 2026-06-23 Structure_Grounding DTOB 15
Denver DEN201c-904 2026-06-23 Structure_Grounding Paramount Underground 15
Denver DEN201c-904 2026-06-23 Structure_Grounding Paramount Underground 15 Missing grounding and bolts
Denver DEN201c-904 2026-06-23 Structure_Grounding DTOB 15 Needs grounding/Ground
Mesa 121e-N150 2026-06-23 Restoration_Trench Foxfiber 15 Mastic patch
Mesa 121d-n141 2026-06-23 Fiber_Tag Ervin 15 Incorrect label
Mesa 121d-N141 2026-06-23 Fiber_Tag Ervin 15 Fix label
Mesa 121-141 2026-06-23 Fiber_Tag Ervin 15 Incorrect label
Mesa 121d-N141 2026-06-23 Fiber_Tag Ervin 15 Fix label
Mesa 121-141 2026-06-23 Fiber_Tag Ervin 15 Incorrect label
Mesa 121d-N141 2026-06-23 Fiber_Tag Ervin 15 Fix label
Stillwater VERO_S_SEGMENT3_CON 2026-06-23 Other TRIPLE J 15 missing pictures
Stillwater VERO_S_SEGMENT3_CON 2026-06-23 Restoration_Core_Hole MB Directional 15 Needs sand and concrete replaced
Denver DEN201c-904 2026-06-24 Structure_Grounding Paramount Underground 14 No grounding
Denver DEN201c-904 2026-06-24 Structure_Grounding DTOB 14
Denver DEN201c-904 2026-06-24 Structure_Grounding DTOB 14 Needs grounding/ground Rod
Denver DEN201c-904 2026-06-24 Structure_Grounding DTOB 14 Missing grounding
Denver DEN201c-904 2026-06-24 Structure_Grounding DTOB 14
Denver DEN201c-904 2026-06-24 Structure_Grounding DTOB 14 Needs ground/Grounding
Denver DEN201c-904 2026-06-24 Structure_Grounding DTOB 14 Needs ground/grounding also bolt
Denver DEN201c-904 2026-06-24 Structure_Grounding DTOB 14 Missing caps and grounding
Denver DEN201c-904 2026-06-24 Structure_Grounding DTOB 14 Missing grounding
Denver DEN201c-904 2026-06-24 Structure_Placement DTOB 14 Volt needs to be replaced with a T 15 due to truck running it over
Denver DEN201c-904 2026-06-24 Structure_Grounding DTOB 14 No ground or end caps
Denver DEN201c-904 2026-06-24 Structure_Grounding DTOB 14 Missing grounding
Denver DEN201c-904 2026-06-24 Structure_Grounding DTOB 14 Missing ground
Mesa 121d-N141 2026-06-24 Fiber_Tag Ervin 14 Fix label
Mesa PHX121 E-DF-PH01 2026-06-24 Restoration_Trench Foxfiber 14 Mastic peel up
Mesa PHX121 E-DF-PH01 2026-06-24 Restoration_Backfill Diamond 14 Needs material around vault
Mesa 121d-N141 2026-06-24 Fiber_Tag Ervin 14 Fix label
Mesa 121x-N141 2026-06-24 Fiber_Tag Ervin 14 Fix label
Mesa 121d-N141 2026-06-24 Fiber_Tag Ervin 14 Fix label
Mesa 121d-N141 2026-06-24 Fiber_Tag Ervin 14 Fix label
Mesa 121d-N141 2026-06-24 Fiber_Tag Ervin 14 Fix label
Mesa 121-176 2026-06-24 Restoration_Other Ervin 14 Vault needs further backfill and tracer needs grounded/ capped
Mesa 121d-N141 2026-06-25 Fiber_Tag Ervin 13 Fix label
Mesa 121d-N141 2026-06-25 Fiber_Tag Ervin 13 Fix label
Mesa 121d-N141 2026-06-25 Fiber_Tag Ervin 13 Fix label
Mesa 121d-N141 2026-06-25 Fiber_Tag Ervin 13 Fix label
Mesa 121d-N141 2026-06-25 Fiber_Tag Ervin 13 Fix label
Mesa 121d-N141 2026-06-25 Fiber_Tag Ervin 13 Fix label
Mesa 121d-N141 2026-06-25 Fiber_Tag Ervin 13 Fix label
Mesa 121d-N141 2026-06-25 Fiber_Tag Ervin 13 Fix label
Mesa 121d-N141 2026-06-25 Fiber_Tag Ervin 13 Fix label
Mesa 121d-N141 2026-06-25 Fiber_Tag Ervin 13 Fix label
Mesa 121d-N141 2026-06-25 Fiber_Tag Ervin 13 Fix label
Mesa 121d-N141 2026-06-25 Fiber_Tag Ervin 13 Fix label
Mesa 121d-N141 2026-06-25 Fiber_Tag Ervin 13 Fix label
Mesa 121d-N141 2026-06-25 Fiber_Tag Ervin 13 Fix label
Mesa 121d-N141 2026-06-25 Fiber_Tag Ervin 13 Fix label wrong DC00#
Mesa 121d-N141 2026-06-25 Fiber_Tag Ervin 13 Fix label
Mesa 121d-N141 2026-06-25 Fiber_Tag Ervin 13 Fix label
Mesa 121-152 2026-06-25 Restoration_Trench Foxfiber 13 Mastic patches
Mesa 121d-N141 2026-06-25 Fiber_Tag Ervin 13 Fix label
Mesa 121d-N141 2026-06-25 Fiber_Tag Ervin 13 Fix label
Mesa 121-152 2026-06-25 Restoration_Trench Foxfiber 13 Mastic patch
Mesa 121-152 2026-06-25 Restoration_Trench Foxfiber 13 Mastic patches
Mesa 121-152 2026-06-25 Restoration_Trench Foxfiber 13 Mastic patches
Mesa 121d-N141 2026-06-25 Fiber_Tag Ervin 13 Fix label
Mesa 121-152 2026-06-25 Restoration_Trench Foxfiber 13 Mastic skip
Mesa 121-152 2026-06-25 Restoration_Trench Foxfiber 13 Mastic skip
Mesa 121d-N141 2026-06-25 Fiber_Tag Ervin 13 Fix label
Mesa 121-152 2026-06-25 Restoration_Trench Foxfiber 13 Mastic patch
Mesa 121d-N141 2026-06-25 Fiber_Tag Ervin 13 Fix label
Mesa 121d-N141 2026-06-25 Fiber_Tag Ervin 13 Fix label
Mesa 121-152 2026-06-25 Restoration_Trench Foxfiber 13 Mastic skip
Mesa 121d-N141 2026-06-25 Fiber_Tag Ervin 13 Fix label
Mesa 121d-N141 2026-06-25 Fiber_Tag Ervin 13 Fix label
Mesa 121d-N141 2026-06-25 Fiber_Tag Ervin 13 Fix label
Mesa 121d-N141 2026-06-25 Fiber_Tag Ervin 13 Fix label
Mesa 121d-N141 2026-06-25 Fiber_Tag Ervin 13 The A-A leg is wrong
Mesa PHX121-E-DF-PH02 2026-06-25 Structure_Grade_Level URIBE 13 Soft scape around vault, Gravel in vault. duct needs trimmed.tracer wire is to long
Mesa 121-E-DF 2026-06-26 Restoration_Trench Diamond 12 Mastic patch, trench needs further power wash before reapplying
Mesa 121-E-DF 2026-06-26 Restoration_Trench Diamond 12 Mastic skip; Mastic peeled up due to flow fill, needs power wash before further application
Mesa 121-E-DF 2026-06-26 Restoration_Trench Ervin 12 Mastic patch
Mesa PH2 EDF 2026-06-26 Grounding Diamond 12 Grounding / conduit needs cap
Mesa 121-E-DF 2026-06-26 Restoration_Trench Foxfiber 12 Mastic patch
Mesa 121-E-DF 2026-06-26 Restoration_Trench Foxfiber 12 Mastic patches
Mesa 121E-DF-ph02 2026-06-26 Structure_Tracer_Wire Diamond 12 Needs grounding
Mesa 121-E-DF 2026-06-26 Restoration_Trench Foxfiber 12 Mastic patch
Mesa PH2 EDF 2026-06-26 Grounding Diamond 12 Grounding/ Cleaning/ Cap conduit
Mesa 121-E-DF 2026-06-26 Restoration_Trench Foxfiber 12 Mastic patch
Mesa PH2 EDF 2026-06-26 Conduit_Other Diamond 12 Conduit Need Cap
Mesa PH2 EDF 2026-06-26 Grounding Diamond 12 Grounding/ Cap conduit/ Bolts needed
Mesa 121E-DF-Ph02 2026-06-26 Structure_Other Diamond 12 Tap conduit
Mesa PH2 EDF 2026-06-26 Conduit_Other URIBE 12 Conduit need Cap
Mesa 121E-DF-Ph02 2026-06-26 Structure_Grounding Ervin 12 Tape conduit / grounding
Mesa 121E-DF-Ph02 2026-06-26 Structure_Grounding URIBE 12 Tape conduit / grounding
Mesa 121E-DF-PH02 2026-06-26 Structure_Grounding URIBE 12 Grounding
Mesa 121E-DF-PH02 2026-06-26 Structure_Grounding URIBE 12 Grounding
Mesa 121-E-DF 2026-06-26 Structure_Grade_Level Diamond 12 Vault needs to be leveled to grade
Mesa 121-E-DF 2026-06-26 Restoration_Trench Diamond 12 Flow fill spilled onto gutter, needs power washed
Mesa 121-E-DF 2026-06-26 Conduit_Sealed Diamond 12 Conduit left unsealed/uncapped
Mesa 121-E-DF 2026-06-26 Conduit_Sealed Diamond 12 Conduit left unsealed/ uncapped
Mesa 121-E-DF 2026-06-26 Conduit_Sealed Diamond 12 Conduit unsealed/ tracer needs grounded to ground rod
Mesa 121-E-DF 2026-06-26 Conduit_Length Diamond 12 Conduit length too long
Mesa 121-E-DF 2026-06-26 Structure_Gravel Diamond 12 SV is missing gravel bed, tracer wire also needs to be properly grounded
Mesa 121-E-DF 2026-06-26 Conduit_Sealed Diamond 12 Conduit left unsealed
Mesa PHX121 E-DF PH01 2026-06-26 Structure_Secure Diamond 12 T8 missing hardware
Mesa PHX121-D-DF PH01 2026-06-26 Structure_Secure Foxfiber 12 SVT15 missing bolts x2
Mesa PHX121-D-DF PH01 2026-06-26 Conduit_Sealed Foxfiber 12 Conduit missing sealant. Bolts buried? x1 needed.
Mesa PHX121 E-DF PH01 2026-06-26 Restoration_Softscape Diamond 12 Irrigation damage/improper grounding cap conduit
Mesa PHX121 E-DF PH02 2026-06-26 Restoration_Trench Foxfiber 12 Mastic patch
Mesa PHX121 E-DF PH01 2026-06-26 Conduit_Other Diamond 12 Missing Stubout to property.
Mesa PHX121 E-DF PH01 2026-06-26 Structure_Gravel Diamond 12 Missing gravel, tracer and ground not bonded, conduit not capped, wet inside vault/irrigation damage.
Mesa 121-E-DF 2026-06-26 Restoration_Trench Foxfiber 12 X3 mastic patch
Mesa 121-E-DF 2026-06-26 Restoration_Trench Foxfiber 12 Mastic patch
Mesa 121-E-DF 2026-06-26 Structure_Other Diamond 12 Vault locking mechanism broken off/ may need to replace vault structure
Mesa PHX121-D-DF PH01 2026-06-26 Conduit_Sealed Foxfiber 12
Mesa PHX121-D-DF PH01 2026-06-26 Conduit_Sealed Foxfiber 12 Conduit missing sealant, bolts x2
Mesa 21997 E Pickett Ct, Queen Creek, Arizona 2026-06-26 Conduit_Sealed Foxfiber 12 Conduit not sealed, missing/buried bolts x2
Mesa PHX121-E-DF PH01 2026-06-26 Conduit_Sealed Foxfiber 12 Missing conduit sealant, SVT15 bolts x2
Mesa PHX121-D-DF PH01 2026-06-26 Conduit_Sealed Foxfiber 12 Missing conduit sealant, bolts x2
Mesa PHX121-E-DF PH01 2026-06-26 Conduit_Sealed Foxfiber 12 Conduit missing sealant
Mesa PHX121 E-DF PH01 2026-06-26 Damaged_Material Diamond 12 Tracer not bonded together. Damaged T8 needs to be replaced.
Mesa PHX121 E-DF PH01 2026-06-26 Structure_Tracer_Wire Diamond 12 Tracer not bonded.
Mesa PHX121 E-DF PH01 2026-06-26 Structure_Tracer_Wire Diamond 12 Tracer not bonded together.
Mesa PHX121 E-DF PH01 2026-06-26 Restoration_Softscape Diamond 12 Irrigation damage vault submerged in water.
Mesa PHX121-D-DF PH01 2026-06-26 Grounding Diamond 12 Strip tracer and bond to ground
Mesa PHX121 E-DF PH01 2026-06-26 Restoration_Softscape Diamond 12 Irrigation damage around vault, tracer not bonded together or ground wire
Mesa PHX121 E-DF PH01 2026-06-26 Structure_Tracer_Wire Diamond 12 Tracer not bonded together.
Mesa PHX121-D-DF PH01 2026-06-26 Structure_Secure Diamond 12 SV missing Bolts x2
Mesa PHX121 E-DF PH01 2026-06-26 Structure_Tracer_Wire Diamond 12 Tracer not bonded together.
Mesa PHX121-D-DF PH01 2026-06-26 Restoration_Backfill Diamond 12 Backfill around vault. Missing bolts x2
Logan 250P163 2026-06-29 Structure_Gravel Hughes 3 9 Lift vault and place a 4 inch base of gravel.
Logan 250P163 2026-06-29 Structure_Tracer_Wire Hughes 3 9 Strip tracer wires and attach them with a wire nut.
Logan 250P163 2026-06-29 Structure_Gravel Ervin 9 Lift vault and place a 4 inch base of gravel.
Mesa 121a-n103 2026-06-29 Structure_Other Ervin 9 Locking mechanism is broken
Logan Lgu147b-N117 2026-06-30 Restoration_Softscape GTO 8 seed for grass
Logan Lgu147b-N117 2026-06-30 Restoration_Softscape GTO 8 seed for grass
Logan Lgu147b-N117 2026-06-30 Restoration_Softscape GTO 8 seed for grass
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch x5
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch x3
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch x3
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch x 4
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch x2
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch x3
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch x3
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch
Mesa PHX121k-N142 2026-06-30 Structure_Grounding Ervin 8 Needs grounded
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch x5
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch
Mesa 121e-N150 2026-06-30 Restoration_Trench Ervin 8 Mastic patch
Mesa 121e-N150 2026-06-30 Restoration_Trench Ervin 8 Mastic patch
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch
Mesa 22878 E Via de Olivos, Queen Creek, Arizona 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 23036 E Via las Brisas, Queen Creek, Arizona
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch x3
Mesa 121e-n150 2026-06-30 Restoration_Trench Ervin 8
Mesa 121e-N150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch x3
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch
Mesa 121-103 2026-06-30 Restoration_Core_Hole Foxfiber 8 Mastic patch
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8
Mesa 121e-n150 2026-06-30 Restoration_Trench Foxfiber 8 Mastic patch
Mesa PHX121k -N142 2026-06-30 Structure_Other Ervin 8 Vault flooded
Mesa PHX121k-N142 2026-06-30 Structure_Other Ervin 8 Needs gravel
Mesa PHX121k-N142 2026-06-30 Structure_Gravel Ervin 8 Needs gravel
Mesa PHX121k-N142 2026-06-30 Structure_Tracer_Wire Ervin 8 Needs to be grounded
Mesa PHX121k-N142 2026-06-30 Structure_Tracer_Wire Ervin 8 Needs grounded
Mesa 121e-n150 2026-06-30 Restoration_Core_Hole Foxfiber 8 Mastic patch
Mesa PHX121k-N142 2026-06-30 Structure_Other Ervin 8 Lid damaged needs replaced
Mesa 121e-n150 2026-06-30 Restoration_Trench Ervin 8 Mastic patch
Mesa PHX121k-N142 2026-06-30 Structure_Grounding Ervin 8 Needs to be grounded
Stillwater VERO_N_SEGMENT3_CON 2026-06-30 Pole_Continuitybond TRIPLE J 8 The tracer wires that are supposed to be in the marker. Post test station are tied to the ground rod.
Stillwater VERO_N_SEGMENT3_CON 2026-06-30 Restoration_Softscape TRIPLE J 8
Stillwater VERO_N_SEGMENT3_CON 2026-06-30 Pole_Continuitybond TRIPLE J 8 No tracer wire in the marker post it’s also full of water
Denver DEN201e-908 2026-07-01 Structure_Grounding DTOB 7 Needs to be grounded
Denver DEN201e-908 2026-07-01 Structure_Grounding DTOB 7 Needs to be grounded
Denver DEN201e-908 2026-07-01 Structure_Grounding DTOB 7 Needs to be grounded
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 seed for grass
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 seed for grass
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 Add dirt seed for grass
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 Add dirt seed for grass
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 157 W 600 S, Logan, Utah, 84321
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 Add dirt seed for grass
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 seed for grass
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 seed for grass
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 remove Rocks seed for grass
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 seed for grass
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 seed for grass
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 add dirt seed for grass
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 seed for grass
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 seed for grass
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 seed for grass
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 seed for grass
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 seed for grass
Logan Lgu147b-N117 2026-07-01 Restoration_Trench GTO 7 Fill trench with flow fill.
Logan Lgu147b-N117 2026-07-01 Restoration_Trench GTO 7 restore sunken trench
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 Add dirt seed for grass
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 Fill sunken ssd path with road base or gravel.
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 Remove rocks, add dirt arround vault and seed for grass
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 seed for grass
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 Add dirt seed for grass
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 Add dirt seed for grass
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 Add dirt seed for grass
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 Add dirt seed for grass
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 Add dirt seed for grass
Logan Lgu147b-N117 2026-07-01 Conduit_Entry GTO 7 burry stubbout sticking out on yard side.
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 Add dirt seed for grass
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 Add dirt seed for grass
Logan Lgu147b-N117 2026-07-01 Restoration_Softscape GTO 7 Remove rocks and seed for grass
Logan Lgu147b-N117 2026-07-01 Restoration_Core_Hole GTO 7 Fill hole in core
Logan Lgu147b-N117 2026-07-01 Restoration_Core_Hole GTO 7 Grind down and top off flow fill
Logan Lgu147b-N117 2026-07-01 Restoration_Core_Hole GTO 7 Fill in hole in core
Logan Lgu147b-N117 2026-07-01 Restoration_Trench GTO 7 Fill hole in trench with flowfill
Mesa PHX121e-N150 2026-07-01 Structure_Tracer_Wire Ervin 7 Needs grounded
Mesa PHX121e-N150 2026-07-01 Structure_Tracer_Wire Ervin 7 Needs grounded
Mesa PHX121e-N150 2026-07-01 Structure_Tracer_Wire Ervin 7 Needs grounded
Mesa PHX121e-N150 2026-07-01 Structure_Tracer_Wire Ervin 7 Needs grounded
Mesa PHX121e-N150 2026-07-01 Structure_Tracer_Wire Ervin 7 Needs grounded
Mesa PHX121e-N150 2026-07-01 Grounding Ervin 7 Needs grounded
Mesa PHX121e-N150 2026-07-01 Grounding Ervin 7 Needs grounded
Stillwater VERO_S_SEGMENT3_CON 2026-07-01 Restoration_Backfill Unassigned 7 Open hole needs backfilled
Stillwater VERO_N_SEGMENT3_CON 2026-07-01 Restoration_Backfill MB Directional 7 Ground sinking
Denver DEN201e-908 2026-07-02 Structure_Grounding DTOB 6 Needs to be grounded
Denver DEN201e-908 2026-07-02 Structure_Grounding DTOB 6 Needs to be grounded
Mesa 121a-N112 2026-07-02 Structure_Grade_Level REDLINE 6 Water inside/ placement and level
Mesa PHX121e-N150 2026-07-02 Restoration_Core_Hole Ervin 6 Dig up needs
Oregon MED_HUT12_DA03_CON 2026-07-02 Unspecified Unassigned 6 Missing slackloop photo
Stillwater VERO_N_SEGMENT3_CON 2026-07-02 Conduit_Depth MB Directional 6 Conduit not at depth entire length of run
Stillwater VERO_N_SEGMENT3_CON 2026-07-02 Restoration_Trench MB Directional 6 80 foot of conduit not at depth conduit needs to be removed and dirt needs to be restored
Logan Lgu147b-N117 2026-07-06 Restoration_Softscape GTO 2 Add dirt seed for grass
Logan Lgu147b-N117 2026-07-06 Locate_Isolation_Switch GTO 2 Remove wire nut and attach them to a Isolation switch. Attach Grounding to Iso Switch as well.
Logan Lgu147b-N117 2026-07-06 Restoration_Softscape Ervin 2 Add dirt seed for grass
Logan Lgu147b-N117 2026-07-06 Structure_Tracer_Wire GTO 2 strip tracer wires and attach them to ground wire with a wire nut.
Logan Lgu147b-N117 2026-07-06 Restoration_Softscape GTO 2 Add dirt seed for grass
Logan Lgu147b-N117 2026-07-06 Restoration_Softscape GTO 2 Add dirt seed for grass
Logan Lgu147b-N117 2026-07-06 Restoration_Softscape GTO 2 add dirt seed for grass
Logan Lgu147b-N117 2026-07-06 Restoration_Softscape GTO 2 Add dirt seed for grass
Logan Lgu147b-N117 2026-07-06 Restoration_Softscape GTO 2 Add dirt seed for grass
Logan Lgu147b-N117 2026-07-06 Restoration_Softscape GTO 2 Add dirt seed for grass
Logan Lgu147b-N117 2026-07-06 Structure_Grounding GTO 2 Needs a ground wire installed and attach under the wire nut with the tracer wire.
Stillwater VERO_S_SEGMENT3_CON 2026-07-06 Missing_Installation Carey 2 No tracer wire
Stillwater VERO_N_SEGMENT3_CON 2026-07-06 Restoration_Backfill MB Directional 2
Stillwater VERO_S_SEGMENT3_CON 2026-07-06 Restoration_Backfill TRIPLE J 2 Homeowner is very upset. He finally got the ditch fixed to where he can mow and the ditch line was rutted up and not back filled properly so he can mow. Please get this corrected ASAP.
Logan Lgu147b-N117 2026-07-07 Conduit_Entry GTO 1 expose stubbout to vault
Logan 26OP035 2026-07-07 Structure_Gravel Alpha One 1 Needs to have gravel in the vault
Logan 26OP035 2026-07-07 Structure_Tracer_Wire Alpha One 1 Hook tracer to ground rod with a ground clamp.
Logan 26OP035 2026-07-07 Structure_Tracer_Wire Alpha One 1 Strip tracer wire and attach them to the ground rod with a grounding clamp.
Oregon MED_HUT10_DA02_CON 2026-07-07 Unspecified Unassigned 1 Missing mastic photos
Stillwater CP_361 2026-07-07 Other TRIPLE J 1 Missing Vault picture
Logan LGU147a-N109 2026-07-08 Structure_Tracer_Wire Ervin 0 strip tracer and attach it with a wire nut.
Oregon MED_HUT10_DA03_CON 2026-07-08 Unspecified Unassigned 0 missing mastic photo